Case Study — SubZero™ V-Series

Eliminating Prime Loss in High-Cycle LNG Fueling Operations

How the SubZero™ V-Series solved extreme thermal cycling challenges and eliminated seal failure at a major satellite LNG station.

Sector
Heavy-duty trucking & logistics
Application
Satellite LNG fueling station
Equipment
SubZero™ V-Series submerged pump
Duty cycle
High-frequency start / stop
SubZero V-Series vertical cryogenic submerged pump, multi-stage tie-rod construction
Case Study

The Challenge

A major logistics hub operating a satellite LNG fueling station was experiencing severe equipment failures. Their existing pumps were failing to maintain prime during the station's demanding duty cycle—frequent start-stop operations for heavy-duty truck refueling. The extreme thermal shock of cycling from ambient temperature down to −162°C (−260°F) multiple times a day was destroying mechanical seals. Furthermore, the station had severe space constraints, requiring the pump to be installed directly inside the storage tank.

Each failure took the dispenser offline for the better part of a shift. For a hub whose fleet schedule depends on predictable turnaround times, an unavailable dispenser does not simply delay one truck — it backs up every vehicle behind it and pushes the delay out into the delivery network.

  • Prime loss between cycles: externally mounted pumps drained back toward the tank during idle periods, so each start began dry.
  • Thermal shock on the seal faces: repeated ambient-to-cryogenic transitions opened running clearances and tore seal faces.
  • No room for external suction piping: the existing pad had no space for a suction drum, piping run or priming arrangement.
Engineering Response

The Solution

Cryovanta supplied a custom SubZero™ V-Series vertical submerged pump. By integrating the pump directly into the tank, we eliminated the need for external suction piping and complex priming. The SubZero's multi-stage tie-rod construction was specifically selected to handle the rapid thermal contraction and expansion without losing internal clearances.

The pump was machined from 304/316L stainless steel and configured with a bottom mounting flange to fit the client's existing tank manway perfectly.

  • Submerged installation: the pump sits below the liquid level, so suction head is always positive and the unit never has to be primed.
  • Tie-rod stage stack: high-tensile tie rods hold the machined stages in compression, so clearances are maintained through every contraction cycle.
  • Drop-in flange match: the bottom mounting flange was cut to the existing manway pattern, so no tank modification was required.
  • Commissioned in place: the unit was installed and brought into service within the station's scheduled maintenance window.
Cryovanta skid-mounted LNG process package with control cabinet, twin stainless pressure vessels and hazardous-area warning labels
The pump was supplied as part of a wider Cryovanta station package — skid-mounted controls, pressure vessels and hazardous-area instrumentation delivered as one commissioned unit.
Scope of Supply

Delivered as a Complete Station Package

Rather than ship a pump and leave integration to the client, Cryovanta delivered the surrounding process equipment on a single skid — pre-piped, pre-wired and factory-tested before it reached site.

Cryovanta skid package coupled to an ambient air vaporizer bank
Skid coupled to the ambient air vaporizer bank — a single mechanical and electrical interface at site.
Front elevation of the station skid showing the control cabinet, gauge board and lockout warning labels
Control cabinet and gauge board, with OSHA-format lockout and no-open-flame signage fitted before shipment.
Outcome

The Results

ZERO Prime Loss

Submerged operation ensures the pump is always ready.

50% Less Maintenance

Tie-rod design and reinforced seals eliminated thermal shock failures.

100% Uptime

The station met its refueling schedule without interruption.

SPACE Optimized

Internal tank installation saved valuable footprint at the station.

Figures reported by the operator over the first year of service. Results depend on duty cycle, medium and site conditions, and are not a performance guarantee.

In Their Words
“We were replacing seals every few months because the pumps kept losing prime. Since installing the Cryovanta SubZero, we've had zero downtime and the maintenance costs have plummeted. It fits perfectly inside our tank footprint.”

— Station Maintenance Manager