Smart Pressure Transmitter

CRYOVANTA™ CXT800 Smart Pressure Transmitter

High-accuracy, two-wire pressure transmitter engineered for LNG, cryogenic, and hazardous-area applications. SIL 3 capable, Zone 0 certified, and built for the most demanding process environments.

Cryovanta CXT800 smart differential pressure transmitter, flanged remote-seal configuration with certification nameplate
  • ±0.04%Accuracy
  • 100:1Turndown
  • 10-YearStability
  • SIL 2/3IEC 61508
  • Zone 0ATEX / IECEx
  • Made in USAHouston, Texas
Data

Core Specifications

ParameterSpecification
Reference Accuracy±0.04% of URL
Turndown Ratio100:1
Long-Term Stability±0.1% URL / 10 years
Output4–20 mA with HART 7
Supply Voltage10.5–45 VDC
Ambient Temperature−40°C to +85°C (−40°F to +185°F)
Process Temperature−40°C to +150°C (−40°F to +300°F) with Halocarbon fill
Ingress ProtectionIP68 / NEMA 4X
Wetted Materials316L SS / Hastelloy C-276 / Tantalum / Sapphire
Housing MaterialsAluminum / 316L SS / Titanium
Fill FluidsSilicone / Halocarbon (cryogenic) / Food-Grade
Design Life20 years minimum
Where It Runs

LNG & Cryogenic Applications

The CXT800 is engineered for the most demanding LNG and cryogenic applications:

  • LNG pump discharge pressure monitoring
  • Cryogenic transfer line pressure
  • Gas compressor suction and discharge
  • LNG storage tank vapor space pressure (Zone 0)
  • Safety instrumented systems (SIL 2/3)
  • Sour gas / H₂S environments (NACE MR-01-75)

Factory-configured for cryogenic service with Halocarbon fill fluid (−40°C to +150°C) and 316L SS, Hastelloy C-276, or Tantalum wetted parts. Custom ranges available up to 6,000 psi.

Select Your Build

Configuration Tiers

The CXT800 platform is available in four configuration tiers. Each tier builds on the previous one.

01

Standard

  • ±0.04% Reference Accuracy
  • 100:1 Turndown
  • 10-Year Stability
  • HART 7
  • 316L SS Wetted Parts
  • IP68 / NEMA 4X
  • 5-digit LCD
  • SIL 2 Capable
  • NIST-traceable Calibration
02

Enhanced

adds to Standard

  • Bluetooth 5.2 (wireless configuration)
  • AI Predictive Diagnostics
  • SIL 2 Certified (Exida report)
  • ISO/IEC 17025 Accredited Calibration
03

Extreme

adds to Enhanced

  • Tantalum Diaphragm
  • Halocarbon Fill Fluid (300°F process)
  • 316L SS Housing (wash-down)
  • ATEX + IECEx (Zone 0)
  • NACE MR-01-75
  • 17-point Temperature Characterization
04

Ultimate

adds to Extreme

  • Sapphire Diaphragm
  • Titanium Housing
  • Ethernet-APL
  • SIL 3 Certified (IEC 61508, HFT=1)
  • OLED Display
  • Full AI Diagnostics
  • Flush Mount Connection
  • DNV GL Type Approved
  • CRN Certified
Side by Side

Feature Comparison Matrix

FeatureStandardEnhancedExtremeUltimate
Measurement
Reference Accuracy±0.04%±0.04%±0.04%±0.04%
Turndown Ratio100:1100:1100:1100:1
Long-Term Stability10 yr10 yr10 yr10 yr
HART 7✓✓✓✓
Bluetooth 5.2—✓✓✓
Ethernet-APL———✓
Materials & Housing
Diaphragm Material316L SSHastelloy C-276TantalumSapphire
Housing MaterialAluminumAluminum316L SSTitanium
Process Temp (fill)StandardStandard300°F300°F
Display5-digit LCD5-digit LCD5-digit LCDOLED
Diagnostics
Predictive Diagnostics—✓✓✓
AI Root Cause Analysis———✓
Certifications
SIL RatingSIL 2 CapableSIL 2 CertifiedSIL 2 CertifiedSIL 3 Certified
ATEX / IECEx——✓ (Zone 0)✓ (Zone 0)
FM / CSA——✓✓
NACE MR-01-75——✓✓
CRN (Canada)———✓
DNV GL———✓
Calibration
Calibration StandardNISTISO 1702517-point17-point
Compliance

Certifications & Approvals

Functional Safety

SIL 2 (HFT=0) and SIL 3 (HFT=1) per IEC 61508, Exida certified with FMEDA report.

Explosion Protection

ATEX: II 1G Ex ia IIC T4 Ga (Zone 0), IECEx: Ex ia IIC T4 Ga (Zone 0), FM: Class I, Div 1, Groups A–D, CSA: Class I, Div 1, Groups A–D.

Pressure Equipment

CRN (Canada) — all provinces, PED 2014/68/EU (Europe).

Marine / Offshore

DNV GL Type Approved.

Corrosion / Sour Service

NACE MR-01-75 / ISO 15156 compliant (Hastelloy and Tantalum wetted parts).

Calibration & Quality

ISO/IEC 17025 accredited calibration laboratory, NIST-traceable calibration included, ISO 9001:2015 quality system.

How to Order

Model Code Structure

Every CXT800 is specified by a nine-position order code. Example: CXT800 – R2 – A1 – H7 – D1 – P1 – C1 – X0 – B0

PositionCodeDescription
Base ModelCXT800Smart Pressure Transmitter
RangeR2, R3, R4Pressure range/span code
HousingA1, S1, T1Aluminum, 316L SS, Titanium
ProtocolH7, H7B, APHART 7, HART 7 + Bluetooth, Ethernet-APL
DisplayD1, D2LCD, OLED
Process ConnectionP1–P4NPT, flanged, flush-mount, sanitary
DiaphragmC1–C3, S1316L SS, Hastelloy, Tantalum, Sapphire
ApprovalX0, XS, XA, XDStandard, SIL, ATEX/IECEx, DNV GL
OptionsB0, B1, B2Calibration and documentation packages
Traceability

Digital Documentation via QR Code

Each CXT800 nameplate includes a QR code linking to our secure verification portal.

  • Product documentation
  • Calibration certificate
  • SIL certificate (FMEDA report)
  • ATEX / IECEx certificate
  • Firmware updates
  • Technical support
Next Step

Ready to specify the CXT800?

Send us the range, process medium, area classification and SIL target, and a Cryovanta engineer will come back to you with a full order code.