Standard
- ±0.04% Reference Accuracy
- 100:1 Turndown
- 10-Year Stability
- HART 7
- 316L SS Wetted Parts
- IP68 / NEMA 4X
- 5-digit LCD
- SIL 2 Capable
- NIST-traceable Calibration
High-accuracy, two-wire pressure transmitter engineered for LNG, cryogenic, and hazardous-area applications. SIL 3 capable, Zone 0 certified, and built for the most demanding process environments.
| Parameter | Specification |
|---|---|
| Reference Accuracy | ±0.04% of URL |
| Turndown Ratio | 100:1 |
| Long-Term Stability | ±0.1% URL / 10 years |
| Output | 4–20 mA with HART 7 |
| Supply Voltage | 10.5–45 VDC |
| Ambient Temperature | −40°C to +85°C (−40°F to +185°F) |
| Process Temperature | −40°C to +150°C (−40°F to +300°F) with Halocarbon fill |
| Ingress Protection | IP68 / NEMA 4X |
| Wetted Materials | 316L SS / Hastelloy C-276 / Tantalum / Sapphire |
| Housing Materials | Aluminum / 316L SS / Titanium |
| Fill Fluids | Silicone / Halocarbon (cryogenic) / Food-Grade |
| Design Life | 20 years minimum |
The CXT800 is engineered for the most demanding LNG and cryogenic applications:
Factory-configured for cryogenic service with Halocarbon fill fluid (−40°C to +150°C) and 316L SS, Hastelloy C-276, or Tantalum wetted parts. Custom ranges available up to 6,000 psi.
The CXT800 platform is available in four configuration tiers. Each tier builds on the previous one.
adds to Standard
adds to Enhanced
adds to Extreme
| Feature | Standard | Enhanced | Extreme | Ultimate |
|---|---|---|---|---|
| Measurement | ||||
| Reference Accuracy | ±0.04% | ±0.04% | ±0.04% | ±0.04% |
| Turndown Ratio | 100:1 | 100:1 | 100:1 | 100:1 |
| Long-Term Stability | 10 yr | 10 yr | 10 yr | 10 yr |
| HART 7 | ✓ | ✓ | ✓ | ✓ |
| Bluetooth 5.2 | — | ✓ | ✓ | ✓ |
| Ethernet-APL | — | — | — | ✓ |
| Materials & Housing | ||||
| Diaphragm Material | 316L SS | Hastelloy C-276 | Tantalum | Sapphire |
| Housing Material | Aluminum | Aluminum | 316L SS | Titanium |
| Process Temp (fill) | Standard | Standard | 300°F | 300°F |
| Display | 5-digit LCD | 5-digit LCD | 5-digit LCD | OLED |
| Diagnostics | ||||
| Predictive Diagnostics | — | ✓ | ✓ | ✓ |
| AI Root Cause Analysis | — | — | — | ✓ |
| Certifications | ||||
| SIL Rating | SIL 2 Capable | SIL 2 Certified | SIL 2 Certified | SIL 3 Certified |
| ATEX / IECEx | — | — | ✓ (Zone 0) | ✓ (Zone 0) |
| FM / CSA | — | — | ✓ | ✓ |
| NACE MR-01-75 | — | — | ✓ | ✓ |
| CRN (Canada) | — | — | — | ✓ |
| DNV GL | — | — | — | ✓ |
| Calibration | ||||
| Calibration Standard | NIST | ISO 17025 | 17-point | 17-point |
SIL 2 (HFT=0) and SIL 3 (HFT=1) per IEC 61508, Exida certified with FMEDA report.
ATEX: II 1G Ex ia IIC T4 Ga (Zone 0), IECEx: Ex ia IIC T4 Ga (Zone 0), FM: Class I, Div 1, Groups A–D, CSA: Class I, Div 1, Groups A–D.
CRN (Canada) — all provinces, PED 2014/68/EU (Europe).
DNV GL Type Approved.
NACE MR-01-75 / ISO 15156 compliant (Hastelloy and Tantalum wetted parts).
ISO/IEC 17025 accredited calibration laboratory, NIST-traceable calibration included, ISO 9001:2015 quality system.
Every CXT800 is specified by a nine-position order code. Example: CXT800 – R2 – A1 – H7 – D1 – P1 – C1 – X0 – B0
| Position | Code | Description |
|---|---|---|
| Base Model | CXT800 | Smart Pressure Transmitter |
| Range | R2, R3, R4 | Pressure range/span code |
| Housing | A1, S1, T1 | Aluminum, 316L SS, Titanium |
| Protocol | H7, H7B, AP | HART 7, HART 7 + Bluetooth, Ethernet-APL |
| Display | D1, D2 | LCD, OLED |
| Process Connection | P1–P4 | NPT, flanged, flush-mount, sanitary |
| Diaphragm | C1–C3, S1 | 316L SS, Hastelloy, Tantalum, Sapphire |
| Approval | X0, XS, XA, XD | Standard, SIL, ATEX/IECEx, DNV GL |
| Options | B0, B1, B2 | Calibration and documentation packages |
Each CXT800 nameplate includes a QR code linking to our secure verification portal.
Send us the range, process medium, area classification and SIL target, and a Cryovanta engineer will come back to you with a full order code.